RSC Publishing


Publishing

 

Cover image for Journal of Environmental Monitoring, select for current issue

Journal of Environmental Monitoring

Cutting-Edge Research on Environmental Processes & Impacts



Subscribers

Non-subscribers

Free access



Paper

J. Environ. Monit., 2009, 11, 1020 - 1027, DOI: 10.1039/b816699d


A novel physiologic sampling pump capable of rapid response to breathing

Larry Lee, Michael Flemmer, Eun Gyung Lee, Martin Harper, Ming-I Lin, William Groves, Andris Freivalds and James Slaven


The merits of using physiologic sampling pumps (PSPs) instead of using constant-flow sampling pumps, i.e., traditional sampling pumps (TSPs), are discussed. A novel PSP that overcomes shortcomings of previous PSP designs is presented. Calibrated valves are used to obviate pump inertia that has limited the system response and accuracy of prior work. Technologies that provide minute ventilation (E) of subjects in real time may therefore be used to the limit of their own accuracies to sample inhalation exposures. Analysis of the design and data from a prototype are presented to show how air sampling can be modulated to follow breathing.

Graphical abstract image for this article  (ID: b816699d)